59

TECHNICAL SPECIFICATIONS: PAGE 161

BAFFLE & GAS DEFLECTOR

TOP VIEW

Baffle Ready

cast in

Polylok Seal

Stainless steel nails drive in, screw out.

See

PAGE 17:

for more Baffle & Gas Deflector options.

BAFFLE TECHNOLOGY FOR THE

SEPTIC SYSTEM

The original Polylok baffle deflects suspended solids

and prevents them from exiting the septic tank.

Installs in minutes when using the Polylok Baffle

Ready Seal. At 38” in length, it can be cut to different

heights to eliminate waste.

Don’t be fooled by

imitations!

FAST INSTALLATION

• Quickly connects in under 30 seconds

• No drilling necessary

• No tracks

• Ideal for inlet and outlet

HIGHEST QUALITY

• Plastic baffle will not deteriorate under constant

attack from gases and chemicals in the septic tank

MOST EFFECTIVE

• No slippage - it’s securely fastened

• Meets ASTM 1227

BENEFITS

• Gas deflector snaps onto baffle

• Deflects suspended solids and prevents them

from exiting the septic tank

• Increases quality of the effluent

• Reduces clogging at the soil-stone interface

• Easy installation, no parts to maintain or clean

• Economical, saves time

PART NUMBERS

• 3015 (Baffle)

• 3023 (Gas deflector)

• 3040 (Stainless steel screws for baffle)

NO DRILLING NECESSARY!

1. Attach baffle ready Polylok seal onto the

mandrel.

2. Pour concrete.

3. Attach baffle to Polylok’s seal with stainless

steel nails.